Skip to content

NHTSA Recall 24V959000: Interlock/lockout (electrical system)

Gillig, LLC reported this safety recall to NHTSA on , covering an estimated 332 vehicles. It affects 2023–2024 Gillig Low Floor.

332
vehicles potentially affected
1
model affected
2025
owners notified (February 12)
NHTSA campaign24V959000
ComponentELECTRICAL SYSTEM › IGNITION › INTERLOCK/LOCKOUT
Report receivedDecember 20, 2024
Owner notificationFebruary 12, 2025
Initiated byManufacturer

Defect

Gillig, LLC (Gillig) is recalling certain 2023-2024 Low Floor style transit buses. The high voltage electric air compressor may not be connected to the High Voltage Interlock Loop (HVIL). Therefore, the HVIL cannot detect a loose or disconnected compressor power cable.

Safety risk

Failure to alert the operator to a power cable issue can increase the risk of injury by electrical shock.

Remedy

Dealers will install an additional electrical harness, extending the HVIL loop to the air compressor, free of charge. Owner notification letters were mailed February 12, 2025. Owners may contact GILLIG customer service at 1-800-735-1500.

Notes

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153) or go to nhtsa.gov.

Vehicles covered by recall 24V959000

Make and modelModel years
Gillig Low Floor2023, 2024