Skip to content

NHTSA Recall 20V323000: Service brakes and 2 other components

Braun Ambulances reported this safety recall to NHTSA on , covering an estimated 31 vehicles. It affects 2 models including the Demers Ambulances Type I (MXP150E).

31
vehicles potentially affected
2
models affected
2020
owners notified (July 21)
NHTSA campaign20V323000
ComponentsSERVICE BRAKES; SERVICE BRAKES, HYDRAULIC › FOUNDATION COMPONENTS › HOSES, LINES/PIPING, AND FITTINGS; SUSPENSION › REAR
Report receivedJune 4, 2020
Owner notificationJuly 21, 2020
Initiated byManufacturer

Defect

Braun Ambulances (Braun) is recalling certain 2019-2020 Demers MXP170E Type I and MXP150E Type I ambulances built on Ram 4500 and 5500 chassis equipped with Compressible Liquid Adaptive Suspension Systems (C.L.A.S.S.), part numbers DS135RS3A, DS135RS3AF and DS135RS3-DM. The rear brake caliper flexible line may have been routed so that it contacts a suspension component, possibly causing excessive wear and a loss of rear brakes.

Safety risk

A worn rear brake caliper flexible line may cause brake fluid leakage which may result in a partial or complete loss of the rear brakes, increasing the risk of a crash.

Remedy

Braun will notify owners and dealers will replace the rear brake caliper flexible lines and hardware, free of charge. The recall began July 21, 2020. Owners may contact Demers customer service at 1-800-363-7591.

Notes

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.

Vehicles covered by recall 20V323000

Make and modelModel years
Demers Ambulances Type I (MXP150E)2019, 2020
Demers Ambulances Type I (MXP170E)2019, 2020

Being listed here means the campaign covers the model year, not that every car was built with the defect or is still unrepaired. Enter your VIN above to check your specific vehicle. Recall repairs are free at authorised dealers. Source: NHTSA, October 2026.