NHTSA Recall 03V190000: Hoses, lines/piping, and fittings (fuel system)
R-VISION, INC. reported this safety recall to NHTSA on , covering an estimated 134 vehicles. It affects 2003 R-Vision Gmt 610.
| NHTSA campaign | 03V190000 |
|---|---|
| Manufacturer campaign | 2003-02 |
| Component | FUEL SYSTEM, GASOLINE › DELIVERY › HOSES, LINES/PIPING, AND FITTINGS |
| Report received | May 8, 2003 |
| Owner notification | May 5, 2003 |
| Initiated by | Manufacturer |
Defect
On certain motor homes, the chassis fuel return line, which is tapped to supply fuel to the generator, has been found to have pressures that exceed the maximum allowed by the generator manufacturer. As a result, if the generator is operated at the same time the chassis engine is running, excess fuel could be delivered to the generator, creating a potential for a generator stall and possible fuel spill.
Safety risk
In the event of a fuel spill, a fire could occur.
Remedy
Dealers will install an approved kit that draws the generator fuel supply directly from the fuel tank. Owner notification began may 5, 2003. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact r-vision at 1-574-268-2111.
Notes
R-vision recall no. 2003-02. Customers can also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-DOT (1-888-327-4236).