NHTSA Recall 00V101000: Hoses, lines/piping, and fittings (fuel system)

ELDORADO NATIONAL reported this safety recall to NHTSA on , covering an estimated 173 vehicles. It affects 2 models including the Eldorado Escort.

173
vehicles potentially affected
2
models affected
2000
owners notified (April 10)
NHTSA campaign00V101000
ComponentFUEL SYSTEM, OTHER › DELIVERY › HOSES, LINES/PIPING, AND FITTINGS
Report receivedApril 7, 2000
Owner notificationApril 10, 2000
Initiated byNHTSA Office of Defects Investigation

Defect

Vehicle description: rear engine buses. These buses are powered by a cng engine and copper tubing was used as vent lines.

Safety risk

The copper tubing is unable to contain the cng venting in the engine compartment.

Remedy

Dealers will replace the 3/8" copper vent line from the lower rear manifold to the roof with 1/2" stainless steel tubing.

Notes

Owner notification began april 10, 2000.owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact eldorado national at 1-909-591-9557.also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-DOT (1-888-327-4236).