Braun Ambulances Express Type III Recalls & Complaints by Model Year
NHTSA lists 5 safety recalls and 0 owner complaints across 7 model years of the Braun Ambulances Express Type III (2019–2025).
Pick your Braun Ambulances Express Type III model year
All Braun Ambulances Express Type III recalls (5)
Every NHTSA safety campaign that lists a Braun Ambulances Express Type III, most recent first, with the model years each one covers.
-
Electrical system
Braun Industries, Inc. (Braun Ambulances) is recalling certain 2021-2026 Chief XL I, Chief XL III, 2021-2025 Express Plus I, Liberty I, 2025 Express III, Select Chief XL I, and Super Chief I emergency vehicles equipped with a Pran system. The battery isolator may fail, causing a loss of electrical systems such as interior, exterior…
Remedy: Braun Service or an authorized dealer will update the software, modify wiring, and replace the battery isolator, free of charge. Owner notification letters were mailed January 12, 2026. Owners may contact Braun…
Model years: 2025
-
Electrical system
Braun Ambulances (Braun Ambulances) is recalling certain 2023-2024 Chief XL I, Chief XL III, Express Plus I, Express III, and Liberty I vehicles. In the event of a short circuit or wiring failure, the firmware in the node may fail to shut off the output pin, resulting in overloaded electrical circuits.
Remedy: Dealers will update the firmware, free of charge. Owner notification letters were mailed June 17, 2024. Owners may contact Braun Ambulances customer service at 1-877-344-9990. Braun Ambulances number for this recall is…
-
Lighting control module (exterior lighting)
Braun Ambulances (Braun) is recalling certain 2023-2024 Chief XL Type I, Chief XL Type III, Express Plus Type I, Express Type III, and Liberty Type I vehicles. The high contact nodes may cause the module mounted turn signals, backup alarm, brake lights, and rearview camera to turn on intermittently or fail to activate.
Remedy: Dealers will replace the node and update the software, free of charge. Owner notification letters were mailed March 26, 2024. Owners may contact Braun customer service at 419-232-7020. Braun's number for this recall is…
-
Electrical system: wiring
Braun Ambulances (Braun) is recalling certain 2020-2023 Chief XL I, Express Plus I, Chief XL III, Liberty I, Super Chief I, Signature Series III, Signature Series I, and 2020-2024 Express III emergency vehicles equipped with Weldon 8X16 Input-Output nodes. In the event of a short circuit or wiring failure, the firmware in the node may…
Remedy: Weldon will update the firmware, free of charge. Owner notification letters were mailed February 28, 2024. Owners may contact Akron Brass customer service at 1-800-228-1161 or Braun customer service at 1-800-488-0359.…
-
Display function (back over prevention) and instrument cluster/panel (electrical system)
Braun Ambulances (Braun) is recalling certain 2019 Chief XL Type I and 2019-2020 Chief XL Type III, 2018-2020 Express Plus Type I and 2019 Express Type III, Liberty Type I, Raider Type I and Super Chief ambulances. The lighting and HVAC display may lock up affecting functions like the back up camera, emergency warning lights, or patient…
Remedy: Braun will notify owners and dealers will remove the defective Vista IV and replace with a new Vista IV, free of charge. The recall began December 18, 2020. Owners may contact Braun Ambulance customer service at…
Model years: 2019
Other Braun Ambulances models
- Chief XL0 complaints
- Chief XL Type I0 complaints
- Chief XL Type III0 complaints
- Express0 complaints
- Express Plus0 complaints
- Express Plus Type I0 complaints
- Liberty0 complaints
- Liberty Type I0 complaints
Source: NHTSA recall and complaint databases and EPA fuel economy data, October 2026. Complaint counts are owner reports to NHTSA, not verified defects. Recall counts are safety campaigns that list this model year; whether a particular car was already repaired depends on its VIN. How this data is compiled.